NEW QUESTION # 32
What is the maximum number of files that can be uploaded in a single operation in Sizer?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 33
Which PowerMax initially ordered configuration provides the fewest available slots for front-end I/O modules per engine?

  • A. PowerMax 8000 multi-engine
  • B. PowerMax 2000 single-engine
  • C. PowerMax 8000 single-engine
  • D. PowerMax 2000 dual-engine

Answer: B


NEW QUESTION # 34
What is the maximum number of Bricks and drives that can be configured in a VMAX 950?

  • A. 2 Bricks and 100 drives
  • B. 8 Bricks and 1920 drives
  • C. 8 Bricks and 288 drives
  • D. 2 Bricks and 96 drives

Answer: B


NEW QUESTION # 35
A script has been designed to create a snapshot using the following command:
symsnapvx -sid <> -sg snapvx_sg establish -name secure_backup -secure -delta 3:23 -nop What is a consideration about the snapshot?

  • A. Is permanent and cannot be terminated
  • B. Can be terminated using the -force flag
  • C. Can be terminated only after 3 days and 23 hours
  • D. Cannot be terminated after 3 days and 23 hours

Answer: C


NEW QUESTION # 36
Which deduplication methods are supported for VMAX all Flash?

  • A. DEFLATE compression algorithm, inline deduplication, and FBA storage Resource Pool
  • B. Adaptive compression Engine, CKD Storage Resource Pool, and Compression I/O module
  • C. Adaptive Compression Engine, Compression I/O module, and LZS Compression algorithm
  • D. Extended Data Compression, inline Deduplication, and LZS Compression algorithm

Answer: C


NEW QUESTION # 37
What parameters are required to calculate Virtual Provisioning Savings?

  • A. Subscribed Total Capacity and Subscribed Allocated
  • B. Subscribed Allocated and Snapshot Capacity Total
  • C. Subscribed Total Capacity and Snapshot Capacity Total
  • D. Snapshot Capacity Total and Modified NonShared

Answer: A


NEW QUESTION # 38
Which types of datasets are subject to inline compression for PowerMax?

  • A. FBA, CKD, eNAS
  • B. FBA and eNAS only
  • C. FBA and CKD only
  • D. eNAS and CKD only

Answer: A


NEW QUESTION # 39
An SRDF/S Consistency Group is created and enabled spanning two PowerMax arrays in a data center.
What is used to prevent multiple hosts from writing to the R1 devices at the same time?

  • A. Embedded management
  • B. Host-based software
  • C. RDF daemon
  • D. Device bias

Answer: B


NEW QUESTION # 40
A PowerMax parent Storage Group (SG) contains two child SGs: SG1 and SG2.
What is a valid Host I/O bandwidth limit setting for this configuration?

  • A. Parent SG: 500
    SG1: 500
    SG2: 400
  • B. Parent SG: 500
    SG1: NOLIMIT
    SG2: 1000
  • C. Parent SG: 400
    SG1: 500
    SG2: 200
  • D. Parent SG: 400
    SG1: 500
    SG2: NOLIMIT

Answer: A


NEW QUESTION # 41
A very small data center is being deployed at a service provider site. New 32 GB FC switches to support Open Systems hosts have been purchased and installed in the data center. Two of the tenants for data storage are from competing small businesses.
Data storage for each tenant is expected to be a maximum of 500 TB. Because tenants are from competing companies, the service provider wants to be able to provide data storage from different arrays to each tenant to guarantee separation of data and information.
Which array is recommended to support these requirements, while occupying the least amount of space in the new data center?

  • A. PowerMax 8000
  • B. VMAX All Flash 950
  • C. VMAX All Flash 250
  • D. PowerMax 2000

Answer: D


NEW QUESTION # 42
An architect uses the following command to collect data from a host when designing a solution in BCSD:
iostat -d -x -t interval count >> hostname.iostat.date.txt
What does the -x flag in the command represent?

  • A. XML format
  • B. Exclude space characters
  • C. Expanded format
  • D. Extended format

Answer: D


NEW QUESTION # 43
Which view of the Unisphere for PowerMax user interface can an architect go to for a heatmap?

  • A. Selected System > Dashboard
  • B. All Systems > Databases
  • C. Selected System > System
  • D. All Systems > Performance

Answer: A


NEW QUESTION # 44
What is the maximum number of Bricks and drives that can be configured in a PowerMax 2000?

  • A. 2 Bricks and 100 drives
  • B. 8 Bricks and 1920 drives
  • C. 8 Bricks and 288 drives
  • D. 2 Bricks and 96 drives

Answer: D


NEW QUESTION # 45
The Reserved Capacity for a Storage Resource Pool (SRP) on a VMAX All Flash array is set to 15%.
A TimeFinder SnapVX snapshot is created for a Storage Group containing 10 devices.
An application is actively performing read and write I/O to these devices. Allocation for the SRP reaches
85%.
What happens to the snapshot?

  • A. Snapshot terminates
  • B. Snapshot fails
  • C. Snapshot persists but new snapshot deltas cannot be created
  • D. Snapshot deltas are allocated from the Reserved Capacity

Answer: C


NEW QUESTION # 46
An administrator is managing historical performance data retention in Unisphere for PowerMax.
Which unit of time is associated with the numerical value they specify for the retention period?

  • A. Months
  • B. Hours
  • C. Days
  • D. Weeks

Answer: C


NEW QUESTION # 47
A PowerMax customer has an existing Masking View for a large database environment. The parent Storage Group in this Masking View has three child Storage Groups with different Service Levels (SLs).
The customer has been experiencing some database performance issues and wants to set the SL to Platinum for all the devices.
When the storage administrator attempts to set the SL on the parent Storage Group, they receive an error and the operation fails.
What is the cause of the error?

  • A. There is insufficient capacity in the Storage Resource Pool
  • B. SLs cannot be set on parent Storage Groups
  • C. Platinum SL is not available for Cascaded Storage Groups
  • D. A child Storage Group already has the Platinum SL applied

Answer: B


NEW QUESTION # 48
Which type of notification is allowed when configuring Unisphere to send out notifications when an alert is triggered?

  • A. HTTP
  • B. TCP
  • C. SNMP
  • D. FTP

Answer: C


NEW QUESTION # 49
What is the best practice sizing guideline for front-end FA utilization on a two-engine PowerMax array?

  • A. 0.7
  • B. 0.5
  • C. 0.8
  • D. 0.6

Answer: A