[Mar-2022] Latest EMC DES-1241 Certification Practice Test Questions [Q35-Q53]

Share

[Mar-2022] Latest EMC DES-1241 Certification Practice Test Questions

Verified DES-1241 Dumps Q&As - 1 Year Free & Quickly Updates


Understanding functional and technical aspects of DES-1241 Specialist - Platform Engineer, PowerStore Exam PowerStore Implementation

The following will be discussed in DELL DES-1241 exam dumps:

  • PowerStore licensing
  • Ethernet switching configuration process
  • Ethernet switching, network requirements, configuration options
  • Initial configuration steps
  • PowerStore networks

 

NEW QUESTION 35
What is a step in configuring the ToR data switches for a Dell EMC PowerStore X?

  • A. Create VLANs for NAS servers
  • B. Configure a port for the discovery laptop
  • C. Configure LACP uplink to management switch
  • D. Create node A port-channel

Answer: A

Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-ntwk-cfg/ configure-port-interfaces-for-powerstore-x-model-node-connectivity?guid=guid-ef6b40ef-82a3-4ebf-99bf- a7bea8d6a586&lang=en-us

 

NEW QUESTION 36
A Storage Administrator needs to address specific fixes within their Dell EMC PowerStore system. Which NDU software upgrade option is used for this situation?

  • A. Software releases
  • B. Drive firmware
  • C. vCenter
  • D. Hotfixes

Answer: C

 

NEW QUESTION 37
Which Dell EMC PowerStore network uses an appliance backplane?

  • A. Inter-cluster management
  • B. ICD
  • C. Inter-node
  • D. MPIO

Answer: C

 

NEW QUESTION 38
Refer to the exhibit.

What type of cable is used for the ToR switch configuration shown for the S5248F-ON switches?

  • A. 100 GigE QSFP28
  • B. 10 GigE SFP optical cable
  • C. 25 GigE Twinax
  • D. 10 GigE Cat 6 Ethernet RJ-45

Answer: A

 

NEW QUESTION 39
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

  • A. Clear the boot mode
  • B. Disable node B boot mode
  • C. Reboot node B
  • D. Return node A to normal mode

Answer: D

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-1000/pwrstr-isg/power-control- procedure-considerations?guid=guid-4352c94e-0ae7-4a2e-8593-9ae135bb9e34&lang=en-us

 

NEW QUESTION 40
Which port is used to SSH from one Dell EMC PowerStore appliance to another?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 41
A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?

  • A. An increased fan speed signal is sent to the surviving fans and the system continues normal operations
  • B. A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires
  • C. CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations
  • D. Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down

Answer: D

 

NEW QUESTION 42
A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?

  • A. Appliance IP address using port 26
  • B. Appliance IP address using port 22
  • C. NAS server IP address using port 22
  • D. NAS server IP address using port 26

Answer: B

 

NEW QUESTION 43
Which experienced administrator role needs to address a warning about configuring VLTi?

  • A. NAS
  • B. VMware distributed switch
  • C. Network
  • D. Storage

Answer: C

 

NEW QUESTION 44
Which component is hot-swappable?

  • A. Expansion IO module
  • B. Fan
  • C. SFP
  • D. BBU

Answer: C

 

NEW QUESTION 45
What describes Dell EMC PowerStore X front-end cabling?

  • A. Management and discovery use the same cables and connections as storage
  • B. Uses VLTi data switch interconnectivity to support vMotion networks
  • C. Uses internal VMware virtual switching and does not require a management network
  • D. Storage and management use the same LACP bonded cable connection

Answer: A

Explanation:
"For PowerStore T model appliances, the individual ports within the system bond could be running in active/active mode or active/passive mode. This state depends on whether Link Aggregation Control Protocol (LACP) has been configured on the network switches. To ensure best resiliency and network performance, it is recommended to enable LACP on the network. For more information about configuring LACP for a PowerStore T model appliance, see the document PowerStore Guide for PowerStore T Models on the PowerStore Info Hub. For PowerStore X model appliances, there is no system bond and no LACP configuration is needed because the link aggregation and failover is handled by the virtual switches within the VMware hypervisor. "

 

NEW QUESTION 46
What describes the power requirements for Dell EMC PowerStore?

  • A. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
  • B. T models require less total power than X models
  • C. X models require less total power than T models
  • D. Lower model numbered systems require less AC line current than higher model numbered systems

Answer: D

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore/pwrstr-plang/power- requirements?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

 

NEW QUESTION 47
Match the correct non-disruptive upgrade process step (answer column) with the correct sub-step (match column).

Answer:

Explanation:

 

NEW QUESTION 48
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?

  • A. Create VLAN for vMotion networks
  • B. Create VLANs for NAS servers
  • C. Configure ports for management on native VLAN
  • D. Configure a port for the discovery laptop

Answer: D

 

NEW QUESTION 49
What describes the power requirements for Dell EMC PowerStore?

  • A. Lower model numbered systems require less input voltage (VAC) than higher model numbered systems
  • B. T models require less total power than X models
  • C. X models require less total power than T models
  • D. Lower model numbered systems require less AC line current than higher model numbered systems

Answer: D

Explanation:
Maximum input power 240 VAC ± 10%, single phase For 100-120V, a customer-supplied step-up transformer is required AC Line Current (operating maximum at 200 VAC) 8.1 A 8.1 A 9.0 A 9.0 A 9.3 A 10.4 A https://www.dell.com/support/manuals/en-us/powerstore-5000/pwrstr-plang/power-requirements-for-powerstore-x-model-and-powerstore-t-model?guid=guid-21e142df-e22c-4bbc-8978-7c6124753654&lang=en-us

 

NEW QUESTION 50
Refer to the exhibit.

A Storage Administrator noticed a solid amber LED. What does this mean?

  • A. Drive rebuilding
  • B. Drive faulted
  • C. Power up
  • D. Drive identification on

Answer: B

Explanation:
Explanation/Reference: https://www.dell.com/support/article/en-pk/sln321266/powerstore-understanding-led-colors-and- states-for-troubleshooting?lang=en

 

NEW QUESTION 51
What is a step in configuring the ToR data switches for a Dell EMC PowerStore X?

  • A. Create VLANs for NAS servers
  • B. Configure a port for the discovery laptop
  • C. Configure LACP uplink to management switch
  • D. Create node A port-channel

Answer: B

 

NEW QUESTION 52
What is the reason for the best practice of leaving 2 Us of space at the bottom of the rack when racking Dell EMC PowerStore systems?

  • A. Leave clearance for wheel roll
  • B. Leave room for serviceability
  • C. Provide better rack stability
  • D. Provide cooling air intake

Answer: B

 

NEW QUESTION 53
......


Conclusion

Training and official guides provide clarity on the circumstances related to the Dell DES-1241 exam. Building yourself for the platform engineer or architect designation gears you for the physical world scenarios. Leveraging the program for Dell Technologies and earning the certification will help in realizing your complete potential. This implies that you achieve acceleration in your career as well as enhance the capabilities of your organization. The test and the respective accreditation are awaiting you. So, to take action today!

 

Latest 2022 Realistic Verified DES-1241 Dumps - 100% Free DES-1241 Exam Dumps: https://www.testkingpass.com/DES-1241-testking-dumps.html